Steel Section Selection and Member Design for Solar Structures: IS 800, Purlins, Columns, Bracing

by Solyug Energy28 November 20260 Comments
How to choose steel grades and sections for solar structures and design purlins, rafters, columns and bracing: slenderness, buckling, capacities, deflection and corrosion protection.

Steel Section Selection and Member Design for Solar Structures

Steel is the main structural material for solar mounting structures, and its selection affects cost, durability and performance. This article covers how to choose grades and sections, what checks each member needs and how STAAD.Pro supports that work. It belongs to our series on solar structure design using STAAD.Pro.

Code edition notice: BIS has published IS 800:2026 (fourth revision), reported as established on 28 October 2026, and trade sources report that IS 800:2007 is scheduled for withdrawal on 28 April 2027. The 2026 edition is reported to be limit-state only and to revise areas such as section classification, lateral-torsional buckling and member interaction. This article describes design concepts that apply under both editions and quotes no clause numbers. Check the edition required by your project and your software version before design.

Steel grades and properties

Structural steel for solar structures is commonly specified to IS 2062, with grades such as E250 and E350 chosen on strength requirements, thickness and availability. For design you need:

•       Yield strength and ultimate tensile strength, which vary with grade and thickness

•       Modulus of elasticity (around 2.0 × 10⁵ MPa in design practice) and Poisson's ratio

•       Density, for self-weight

•       Weldability and toughness requirements, particularly in cold or coastal environments

Cold-formed light-gauge sections are made from strip steel to their own product standards, and their design strength depends on the strip grade and the forming process. Use the supplier's certified properties and the specification, rather than assuming the same values as hot-rolled plate.

Hot-rolled and cold-formed sections

Type

Typical uses

Strengths

Points to watch

Hot-rolled channels, angles, I-sections

Rafters, columns, bracing

Robust, simple to design under IS 800, well covered in software

Heavier, more steel on long spans

Hollow sections (square, rectangular, circular)

Columns, rafters

Good torsional and buckling performance, compact

Connection details, internal corrosion if not sealed

Cold-formed C, Z, sigma sections

Purlins, sometimes rafters

Light, efficient in bending

Local and distortional buckling, lateral-torsional buckling, thin sections, perforations, designed under cold-formed provisions such as IS 801

Angles

Bracing, ties

Easy to connect

Eccentric connection effects, slenderness

Aluminium extrusions

Rails, some roof systems

Light, corrosion resistant

Different design code, thermal movement, cost

 

IS 801 covers cold-formed light-gauge structural members in general building construction, and aluminium structures are covered separately (for instance by IS 8147). Do not apply hot-rolled section rules to thin cold-formed sections.

Member roles and typical demands

Member

Main actions

Typical governing checks

Purlins

Bending about the strong axis, some weak-axis bending and torsion, shear

Lateral-torsional buckling under uplift, deflection, web crippling at supports, bolt holes

Rafters

Bending and axial force

Combined axial and bending, lateral restraint from purlins

Columns

Axial compression or tension plus bending

Buckling, combined actions, base connection

Bracing

Axial tension and compression

Slenderness, tension with reversal, connection

 

Slenderness

Slenderness is the ratio of effective length to radius of gyration and governs how easily a compression member buckles. Codes also set maximum slenderness limits, which differ for members that carry dead and imposed load and for those that carry only wind or seismic load, and for tension members. Use the code's table for the edition in force. Light bracing that is slender in compression often relies on tension action alone, which is acceptable only if the design and connections reflect it and reversal is considered.

Local buckling and section classification

Thin plate elements in a section can buckle locally before the member reaches its full strength. Codes classify hot-rolled sections by plate slenderness (for example plastic, compact, semi-compact and slender) and reduce capacity accordingly. Cold-formed sections use effective-width concepts and consider local and distortional buckling directly. A cold-formed section is not "just a lighter channel", and the supplier's tested or calculated properties should support the design.

Lateral-torsional buckling

A beam bent about its strong axis can twist and move sideways if its compression flange is not restrained. In solar tables the effect is easy to overlook:

•       Under downward load, the top flange of a purlin is in compression and is often restrained by the modules and clamps (to a degree that must be justified, not assumed).

•       Under wind uplift, the bottom flange goes into compression, and may be free between supports or rafters. Lateral-torsional buckling can then govern.

•       Anti-sag rods, sag bars or bracing between purlins and rafter connections provide restraint, and their presence should be checked in the model and reflected in unbraced length parameters.

Bending, shear and axial capacity

•       Bending capacity depends on section modulus, the section class and lateral restraint. Reduce it where buckling governs.

•       Shear capacity uses the web area, with a reduction where the web is thin and may buckle in shear. Combined bending and shear matter near supports and at splices.

•       Axial tension uses net area at bolt holes and a check on connection failure modes such as block shear.

•       Axial compression uses effective length and the buckling curve for the section, and should be checked about both axes.

Combined forces

Columns and rafters carry axial force and bending at the same time, often biaxial. The code gives interaction formulas that combine utilisation under each action. For members that reverse (tension in one case, compression in another), check each case rather than a single combination.

Deflection

Limits on deflection protect modules, claddings, drainage and appearance. Check purlins and rafters under serviceability combinations, both downward and uplift, using limits from the project design basis and the module manufacturer's requirements, as well as the code table. Remember that deflections of rafters and purlins add up in the direction normal to the module plane.

Corrosion protection and durability

Solar structures stand outdoors for 25 years or more. Durability is a design requirement:

•       Hot-dip galvanising is the usual protection for steel in most environments. The coating thickness should be specified according to the environment and the applicable galvanising standards, with attention to cut edges, holes and field welds.

•       Aggressive environments (coastal, industrial, high-humidity, saline soils) may need heavier coatings, duplex coating systems or different materials.

•       Below-ground and splash-zone elements are the most vulnerable, so piles and column bases need special attention and, sometimes, a sacrificial allowance in section thickness.

•       Fasteners and bimetallic contact with aluminium need compatible materials and isolation to avoid galvanic corrosion.

•       Drainage and detailing should avoid water traps in hollow sections.

How STAAD.Pro assists and what still needs independent checks

STAAD.Pro can run steel design checks against supported codes, report utilisation ratios and optimise sections. Bentley's solar webinar content also covers cold-formed section design and buckling analysis of custom slender sections. The program is only as good as its inputs. Independent checks are still needed for:

•       Effective length and unbraced length parameters, which reflect restraint conditions the software cannot see

•       Cold-formed section properties and local or distortional buckling where supplier data is required

•       Connections, bolt groups and base plates

•       Edition support. Confirm which code editions your STAAD.Pro version implements

•       Corrosion allowance and coating

•       A hand calculation of at least the governing members

Our articles on solar structure design calculations and common mistakes in STAAD.Pro solar design describe such checks in more detail.

Common mistakes

•       Using hot-rolled design rules for cold-formed sections

•       Ignoring lateral-torsional buckling under uplift

•       Assuming modules restrain purlins without evidence

•       Overlooking bolt holes in net sections

•       Selecting very thin sections with no corrosion allowance

•       Using a code edition that the project does not accept

Frequently asked questions

Which steel sections are used in solar structures?

Cold-formed C and Z purlins, hot-rolled or hollow rafters and columns, and angle or flat bracing, with the choice driven by span, load, cost, availability and durability.

How does IS 800 apply to solar structure design?

It provides the limit-state design rules for hot-rolled steel members and connections, and cold-formed members follow IS 801. Confirm the edition required on your project, since IS 800:2026 has been published.

Why does uplift affect purlin design?

Under uplift, the unrestrained flange goes into compression, which can cause lateral-torsional buckling, and the load direction reverses compared with gravity.

Can STAAD.Pro design cold-formed sections?

Bentley's solar webinar content describes cold-formed section design and buckling analysis capability, but engineers must confirm the code, section data and parameters used.

How thick should the galvanising be?

It depends on the environment and the applicable standards and project specification, so it cannot be stated generally. Specify it for the site.

Do I need to check connections separately?

Yes. Member utilisation does not cover bolts, welds, base plates and anchors.

Conclusion

Section selection balances strength, stiffness, weight, durability and buildability. A design that records its restraint assumptions and checks uplift, buckling, connections and corrosion will stand up better to review and to the weather.

Structural member design support for your project

Solyug Energy's solar structural consultancy covers member sizing, connection checks and design validation, including material optimisation between steel and aluminium as described on the service page. For wind-governed designs see our STAAD Pro wind analysis service, or get in touch.

#solar steel structure design#IS 800#purlin design#cold-formed steel#hollow sections#column design#lateral torsional buckling#galvanising#section selection#STAAD.Pro member design

Comments (0)

No comments yet. Be the first to share your thoughts!

Leave a Comment

Chat with us
SOLYUG ENERGY
SOLYUGENERGY

SOLAR DESIGN & CONSULTANCY

Let's Engineer Your Next Solar Project.

Looking for reliable solar engineering and design solutions? Partner with Solyug Energy for precise solar layouts, detailed engineering, structural consultancy and performance-driven project designs. With 520MW+ project experience across India, Africa and the Gulf, our team is ready to support your next solar project.
520MW+
PROJECT EXPERIENCE
5+
YEARS EXPERIENCE

Explore Our Solar Engineering Expertise

Serving EPCs, developers & businesses across India, Africa & the Gulf.