Solar Structure Modelling in STAAD.Pro: Step-by-Step Tutorial from Input Data to Report
Step-by-Step Solar Structure Modelling in STAAD.Pro
A solar structure model is only as good as the decisions made before the first node is drawn. This tutorial follows the sequence experienced designers use: collect inputs, build the geometry, define properties and supports, apply loads, analyse, review and report. It is part of our series on solar structure design using STAAD.Pro.
Menu names and dialogs change between STAAD.Pro releases, so this article describes the workflow rather than click-by-click menus. Where it shows input commands, they follow the structure documented in Bentley's technical reference, but you should confirm syntax against the help of the version you use.
Stage 1: Prepare the inputs
1. Collect project input data
Gather module dimensions and weight, table configuration and tilt, column and purlin spacing, ground clearance, steel grade, site wind parameters, soil or roof information and the governing codes. Missing data should be listed as assumptions in the design basis, not hidden in the model.
2. Understand the solar structure geometry
Draw or sketch the table in elevation and plan. Identify the front and rear columns, the rafter slope, the purlin locations and the bracing. Decide whether one two-dimensional frame is enough for a preliminary check, or whether a full three-dimensional model of several frames is needed to capture purlin continuity and bracing behaviour. For final design, a three-dimensional model is normal practice.
3. Identify the structural members
List the members by role: purlins, rafters, front columns, rear columns, sway or knee bracing, cross bracing and any ties. Each role may need a different section and different design parameters.
Stage 2: Build the model
4. Create the structural grid
A grid helps when many identical frames are repeated along a table. Define the spacing along the table length (frame spacing) and the frame geometry across it.
5. Create nodes
Place nodes at every point where members meet, change section, receive a support or carry a significant point load. For a tilted rafter, node heights follow from the tilt angle. For example, a 4.4 m sloping length at 15° rises by about 1.14 m and spans about 4.25 m horizontally.
6. Create beams and members
Join nodes with members. Ensure that purlins connect to the rafters at the same nodes, not near them. Members that cross without a shared node are not connected in the analysis.
7. Define steel material properties
Assign the modulus of elasticity, Poisson's ratio, density and thermal coefficient for the steel grade used. Confirm that the yield strength used for code checks reflects the grade and thickness of the actual section. This matters in particular for cold-formed sections, whose design strength is not the same as that of thick hot-rolled sections.
8. Assign cross-sections
Pick sections from the library or define user-provided properties for proprietary or cold-formed profiles. Check that the section orientation is right (strong axis versus weak axis) because purlin and rafter orientation strongly affects the results.
9. Define member properties and orientation
Use beta angles or local-axis settings to orient channels, Z-purlins and angles correctly relative to the loads. A wrongly rotated purlin will quietly bend about its weak axis in the model while you believe it bends about the strong axis.
10. Define supports
Choose supports that represent the real foundation. A pile or pedestal embedded in soil is not a perfect fixed support, and a base plate with two anchor bolts is not a perfect pin. Decide, state and justify the idealisation. Run a sensitivity check with a more flexible support when the result is sensitive to it, since foundation stiffness changes the column moments and the deflections.
11. Assign member releases where justified
Release moments at connections that are genuinely pinned, for example bolted purlin-to-rafter cleats designed as simple connections. Bentley's modelling notes mention axial releases to handle temperature strains where appropriate. Every release should be backed by the connection detail, because a release removes stiffness and can make the model unstable.
12. Check model connectivity
Plot the model, switch on node and member numbers, and look for gaps, duplicated members and free-ended members. Run a quick check on a simple load, such as self-weight, and confirm the reactions add up to the weight you expect.
Stage 3: Loads
13. Define load cases
Create primary cases for dead load (including self-weight), module and accessory load, imposed or maintenance load, wind in each relevant direction (typically pressure and suction, for each of the principal directions), and seismic where required.
14. Apply loads
Wind load is calculated first, outside the software, from IS 875 (Part 3) and project-specific aerodynamic data, then converted into pressures on the module plane. The pressure is then applied as member loads on purlins (normal to the module plane) or as nodal loads at purlin-rafter joints. The full procedure is in how to apply wind loads in STAAD.Pro for solar structures, and the calculation is in solar structure wind load calculation as per IS 875 Part 3.
15. Define load combinations
Combination cases combine the results of primary cases with factors. Bentley's documentation describes the command in the form LOAD COMBINATION n title, followed by pairs of load case number and factor. See load cases and load combinations for solar mounting structures to decide which factors apply. Remember that combining results algebraically is only valid for linear analysis.
A schematic input file
The example below is a single illustrative frame with a 15° tilt and invented loads. It shows structure, not a design. Section names, coordinates and load values are placeholders, and signs depend on how members are oriented, so always plot the loads to confirm direction.
STAAD SPACE SOLAR TABLE ILLUSTRATIVE FRAME UNIT METER KN JOINT COORDINATES 1 0 0 0; 2 0 1.0 0; 3 4.25 0 0; 4 4.25 2.139 0 MEMBER INCIDENCES 1 1 2; 2 3 4; 3 2 4 MEMBER PROPERTY INDIAN 1 2 TABLE ST ISMB100 3 TABLE ST ISMC100 SUPPORTS 1 3 PINNED LOAD 1 DEAD LOAD SELFWEIGHT Y -1 MEMBER LOAD 3 UNI GY -0.17 LOAD 2 WIND DOWNWARD MEMBER LOAD 3 UNI Y -0.92 LOAD 3 WIND UPLIFT MEMBER LOAD 3 UNI Y 1.15 LOAD COMBINATION 101 1.5 DL + 1.5 WL DOWN 1 1.5 2 1.5 LOAD COMBINATION 102 0.9 DL + 1.5 WL UP 1 0.9 3 1.5 PERFORM ANALYSIS PRINT SUPPORT REACTION FINISH |
The commands for joints, members, properties, supports, loads, combinations and analysis follow the structure shown in Bentley's technical reference. Check the exact syntax, the section table names and your code-specific parameters in the help of your installed version before relying on any script.
Stage 4: Analyse and review
16. Run the structural analysis
Run the analysis and read the output file or message window.
17. Review analysis warnings
Warnings about instability, zero stiffness, unconnected nodes or excessive displacement mean something is wrong in the model. Do not proceed to code checks until they are understood and resolved.
18. Check support reactions
Compare the sum of vertical reactions to the sum of applied vertical loads for each primary case. For wind uplift, the vertical reactions should be upward and of the size you expect from your hand calculation. Support reactions go on to foundation design, so errors here travel far.
19. Review bending moments
Look at the bending moment diagrams for purlins, rafters and columns. Peaks at unexpected locations often point to wrong releases or supports.
20. Review shear forces
Check shear near supports and at connections. High shear on thin cold-formed webs can govern the section.
21. Review axial forces
Columns in solar tables see compression under downward load and tension under uplift. Make sure both are checked, and that bracing members change between tension and compression as the wind direction changes.
22. Review displacement
Compare maximum deflections with the limits in the design basis. For purlins and rafters, check both downward and uplift cases. Check the global sway of the table as well, since excessive movement can stress modules.
Stage 5: Design checks and documentation
23. Perform member design checks
Set the design code and parameters (effective lengths, unbraced lengths, section type and so on) and run the code check. Parameters set wrongly, for example an unbraced length that ignores purlin restraint or its absence, change the result significantly. Remember that cold-formed sections follow different rules than hot-rolled ones, and that IS 800:2026 has been published to replace IS 800:2007, so confirm the edition and software support.
24. Review utilisation ratios
Review ratios for the governing combination and for each member group. Ratios close to 1.0 deserve a second look, as do very low ratios, which suggest over-design or a missing load. An acceptable ratio does not remove the need to check connections and foundations.
25. Prepare structural reports
Report the design basis, loads, model views, reactions, member forces, utilisation ratios and the final member schedule. Include enough data for a reviewer to reproduce key results.
Common modelling mistakes
• Members crossing without shared nodes
• Wrong beta angles for purlins and rafters
• Fixed supports where a flexible foundation is more realistic
• Missing self-weight or module dead load
• Wind applied in the wrong direction or sign
• Combinations that omit the uplift case with reduced dead load
Frequently asked questions
How do you model a solar structure in STAAD.Pro?
Build a frame model of columns, rafters, purlins and bracing with nodes at every connection, assign sections and material, define supports and releases, apply dead and wind loads, create combinations, analyse and check the members.
Which supports should be used for a solar table?
Use the support that matches the real foundation and base connection. Many designs begin with pinned bases and test fixed or spring supports to see how sensitive the results are.
Do I need a 3D model or is a 2D frame enough?
A 2D frame is useful for a preliminary check. Final design normally uses a 3D model so that purlin continuity, bracing and wind from different directions are captured.
How do I check the model is connected properly?
Plot the model with node and member numbers, run a simple self-weight case and verify that reactions equal the total weight. Warnings about instability point to connectivity problems.
What should I look for when reviewing results?
Reaction balance, sensible diagram shapes, deflections within limits and utilisation ratios for all governing combinations, including uplift.
Can I automate model generation?
Bentley mentions API-based automation for generating solar structure models. This is useful for repetitive layouts but still needs engineering checks of inputs and outputs.
Conclusion
Careful modelling is a discipline of small decisions: connectivity, orientation, supports, releases and loads. Follow the sequence, check each stage against a hand calculation and the model becomes a reliable basis for design rather than a source of confident but wrong numbers.
Get your solar structure modelled and checked
Solyug Energy's structural consultancy for solar projects includes STAAD.Pro modelling, member checks and engineering reports. For wind-governed designs see our STAAD Pro wind analysis service, or send your project details through the contact page.