Ground-Mounted Solar Structure Analysis Using STAAD.Pro: Model, Loads, Stability and Foundations
Ground-Mounted Solar Structure Analysis Using STAAD.Pro
Ground-mounted solar plants load the structure and the soil together. The steel frame must be strong and stiff, and the foundation must resist uplift, overturning, sliding and settlement in the actual ground conditions. This article explains the main configurations, the load path, the key checks and how to build a STAAD.Pro model for a fixed-tilt ground table. The wider workflow is in our pillar guide on solar structure design using STAAD.Pro.
What ground-mounted solar structures are
A ground-mounted structure holds modules above the ground at a fixed tilt (or, for trackers, a variable one) and transfers all loads into foundations in the ground. Bentley lists ground-mounted, roof-top, pole-mounted and floating solar as the common mounting types. This article deals with fixed-tilt tables, which are the most common utility and C&I configuration. Tracker structures involve torsional and dynamic wind effects and need additional specialist assessment.
Structural configurations
Common fixed-tilt arrangements differ in the number of module rows (for example 1, 2, 3 or 4 in portrait), the number of support lines and the span between them:
• Two-column frame tables: a front and a rear column per frame, a sloping rafter, purlins across the rafters.
• Multi-column tables: additional intermediate supports for longer sloping lengths.
• Cantilevered purlins and rafters: overhangs beyond the end columns reduce member spans but create eccentric loads.
• Braced and unbraced frames: longitudinal and transverse bracing provides stability, while some tables rely on moment-resisting connections or foundation fixity.
Main components
Component | Function | Common forms |
Columns and posts | Carry axial load, bending and uplift into foundations | Hot-rolled sections, hollow sections, cold-formed sections |
Rafters | Inclined beams between columns | Channels, hollow sections, cold-formed profiles |
Purlins | Span between rafters, carry modules | Cold-formed C or Z sections, channels |
Bracing | Lateral stability | Angles, flats, rods, hollow sections |
Base connection | Joins column to foundation | Base plate with anchor bolts, embedded section |
Foundation | Transfers loads to soil | Driven pile, ground screw, concrete pier, ballast |
Structural load path
Wind and dead load on modules go into purlins as line loads. Purlins deliver point loads to rafters. Rafters deliver axial force, shear and moment to columns and bracing. Columns deliver compression, tension, shear and possibly moment to the foundation, which transfers them to soil by bearing, skin friction and lateral resistance. A failure anywhere along the path can govern, which is why each element and connection is checked.
Loads and wind effects
Dead load is small compared with wind for typical tables. Wind creates:
• Downward pressure, which governs compression in columns and bearing on foundations
• Uplift suction, which governs tension in columns, anchor bolts and pile pull-out
• Horizontal force, which governs bracing, lateral pile design and sliding
• Overturning moment, which produces differential tension and compression between front and rear columns
IS 875 (Part 3) does not provide pressure coefficients for tilted solar arrays, so engineers apply open-roof provisions with judgement and consider eccentric load distribution and row sheltering. See solar structure wind load calculation as per IS 875 Part 3 for details, and dead, imposed and wind loads on solar structures for the other loads.
Developing the STAAD.Pro model
1. Set up the geometry
Create nodes for column bases, column tops, rafter ends and purlin positions, using the table tilt to compute heights. For a typical table with several identical frames, build one frame and copy it along the table length at the frame spacing.
2. Add purlins and bracing
Connect purlins across the rafters at the purlin spacing, with their orientation set so the strong axis resists loads normal to the module plane. Add bracing in the plane of the columns and between frames.
3. Assign sections and material
Assign hot-rolled or cold-formed profiles and the steel grade. Where cold-formed sections need properties not in the program library, enter them as user-defined properties derived from the supplier's data.
4. Define supports
Model supports at the foundation top or at an equivalent depth to fixity if the pile transmits moment. Pinned supports are a simple starting point. Where the foundation provides rotational restraint, a flexible spring (from soil-structure interaction data) is more realistic than rigid fixity, and results can be sensitive to the choice. State the assumption.
5. Apply loads and combinations
Apply dead loads, wind pressure and uplift for each direction and define strength and serviceability combinations. See load combinations for solar mounting structures.
6. Analyse and check
Run the analysis, review reactions and member forces, then run code checks. The modelling steps are detailed in solar structure modelling in STAAD.Pro, step by step.
Stability checks
• Uplift: resisting force from dead load and foundation pull-out capacity against factored wind uplift, using the reduced dead load factor.
• Overturning: the stabilising moment of weight and foundation reaction against the overturning moment from wind.
• Sliding: horizontal resistance of the foundation against the horizontal wind component and any sliding of ballasted or shallow bases.
Member design and deflection
Check columns for axial force and bending with buckling, rafters and purlins for bending, shear and lateral-torsional buckling (particularly under uplift when the free flange is in compression), and bracing for tension and compression. Check deflection of purlins and rafters against the limits in the design basis, and the global sway of the table.
Foundation supports and soil
Typical foundation types for ground-mounted tables are driven piles, ground screws, bored cast-in-situ piles, concrete piers and ballasted blocks. The choice depends on soil type, groundwater, refusal conditions, contamination and corrosion, and cost. The structural analysis does not determine any of this.
Geotechnical considerations include:
• Soil bearing capacity and the pull-out resistance of piles
• Lateral load resistance of piles under wind
• Presence of rock or boulders, causing refusal
• Corrosivity of soil and groundwater
• Seasonal variation, expansive soils and frost
A site-specific geotechnical investigation, plus pile load testing (pull-out, lateral and compression) on the project site, normally forms part of the design, as discussed in solar structure foundation design and support considerations.
Foundation reactions
For each support, extract maximum compression, uplift, lateral shears and any moments for each governing combination. Present them in a table with clearly marked factored or unfactored status, because geotechnical and foundation design uses both. Avoid sending one summary number and no load case information.
Practical workflow summary
1. Confirm site data, soil investigation and design basis
2. Fix the structural layout
3. Calculate loads
4. Build and verify the STAAD.Pro model
5. Run combinations and review reactions and forces
6. Optimise sections and check connections
7. Issue reactions for foundation design
8. Feed foundation test results back into the structure if support conditions change
9. Prepare drawings and the report
Common mistakes
• Using a single foundation design for all sites without checking local soil
• Fixing bases without confirming that the foundation supplies moment resistance
• Ignoring eccentric wind pressure on rafters
• Ignoring the uplift case with reduced dead load
• Not coordinating the structure with terrain slope and grading
Frequently asked questions
What are the main components of a ground-mounted solar structure?
Columns, rafters, purlins, bracing, base connections and foundations such as piles, ground screws or concrete piers.
What checks does a ground-mounted solar structure need?
Member strength and buckling, deflection, connection strength, uplift, overturning, sliding, and foundation capacity for compression, uplift and lateral loads.
How are STAAD.Pro reactions used for foundations?
Each support's compression, uplift, shear and moment, by combination, are given to the foundation designer, who checks pile or footing capacity using soil data.
Why does soil matter for a solar structure?
Soil determines the foundation type, its capacity in tension and lateral loading, and the support stiffness assumed in the model.
Can one STAAD.Pro model cover a whole plant?
Typically a model represents a typical table or table family, with variations for end tables, edges, slopes and soil zones where design conditions change.
Are tracker structures analysed the same way?
Not entirely. Trackers add rotation, torsional and dynamic wind effects and normally need specialist supplier data.
Conclusion
A ground-mounted structure is an interaction between steel, wind and soil. A consistent model, a clear load path and a coordinated foundation design give a structure that can be justified on paper and built on site.
Ground-mount structural design support from Solyug Energy
Solyug Energy supports MW-scale ground-mounted solar projects with design and engineering, and provides solar structural consultancy including ground-mounted structural design and STAAD.Pro analysis. Share your layout and soil information through our contact page.